Prisma Teknik
Box 5 Mariestadsvägen 28
543 21 TIBRO, Sweden
Tel: +46 (0)504 400 40
Fax: +46 (0)504 141 41
www.prismateknik.se
Models
- TS-903F, TS-904F, TS-907F, TS-908F very similar with slightly different features
- Digital Acoustic Pedestrian Signal, DAPS
Figure B-13. Prisma TS-995 pedhead-mounted beaconing loud speaker
Standard features
TS-903F, TS-904F, TS-907F, TS-908F
WALK indication
- Rapidly repeating percussive tone
- Vibrating arrow on TS-907 and TS-908 only
Other
- Speaker at pushbutton
- Pushbutton locator tone
- Tactile arrow
- Automatic volume adjustment within range of 55–95 dB
- Actuation indicator — light and tone — on TS-903 and TS-907 only
- Crosswalk tactile map (Braille map)
- Fault indicator
Optional features
- 10 different tones available
- Night switch to deaden sound
- Double-ended arrow available for use on medians and right-angle arrow available for use with exclusive pedestrian phasing, where there is a single pushbutton on a corner
DAPS
WALK indication
- Rapidly repeating percussive tone
- Vibrating arrow
Other
- Speaker at pushbutton
- Pushbutton locator tone
- Tactile arrow
- Automatic volume adjustment within range of 55–95 dB
- Actuation indicator — light and tone
- Crosswalk tactile map (Braille map)
- Fault indicator
Optional features
- 10 different tones available by setting with PDA
- Custom speech WALK messages, recorded and programmable with PDA
- Additional beaconing speaker (TS-995) for mounting at overhead location
- Night switch to deaden sound
- Double-ended arrow available for use on medians and right-angle arrow available for use with exclusive pedestrian phasing, where there is a single pushbutton on a corner
- Extended button press features
- Pushbutton information message 1&ndash16; seconds
Installation notes
Numerous features of DAPS model are programmable with PDA.
Volume min/max levels are adjustable by installer.
Step-down transformer available for mounting in the pedestrian signal head for U.S. installation
Tactile arrow is mounted horizontally on top of device, allowing some latitude in placement of APS on pole, while still making it possible to align the arrow parallel with the associated crosswalk.
Wiring colors may conform to European standards rather than U.S. standards